SEVCON CONTROLLERS

<<< back to main menu

ACCELERATOR
ACE PLUS
CALIBRATOR
CLEAR VIEW DISPLAY
DVT
ESPAC
GEN4
GPAC
HVLP
HYPAC
MC150
MC250
MC350
MC400
MC610
MCG
MCM
MICROMOS
MICROPAK
MILLIPAK 4QPM
MILLIPAK PMAC
MILLIPAK PUMP
MILLIPAK SBPM
MILLIPAK SEM
MK7
MOS90
NANO
PCPAK
POWER GAUGE
POWERPAC
POWERPAK PUMP
POWERPAK SEM
POWERPAK SERIES
PST
SC1000
SC2000

SEVCON - motor controller
MICROMOS & SC1000 error codes

Green LED Description
OFF No power-up
2 FLASHES Wrong start procedure - invalid sequence
3 FLASHES Motor output short-circuit to B-
4 FLASHES Motor output short-circuit to B+
5 FLASHES Motor contactor circuit open
6 FLASHES Accelerator fault
7 FLASHES Battery voltage fault
8 FLASHES Thermal cutback
9 FLASHES Battery voltage below 18V

SEVCON - motor controller
MOS90 error codes

Green LED Description
OFF No power-up or controller internal error
2 FLASHES Wrong start procedure - invalid sequence
3 FLASHES Motor output short-circuit to B- or bypass contactor welded
4 FLASHES Direction contactor welded
5 FLASHES Motor contactor circuit open or direction contactor not close
6 FLASHES Accelerator fault
7 FLASHES Battery voltage fault
8 FLASHES Thermal cutback

SEVCON - motor controller
MILLIPAK 4QPM error codes

Green LED Description
ON No fault
OFF Controller internal error or no keyswitch voltage
1 FLASH Personality out of range
2 FLASHES Illegal start condition
3 FLASHES Motor MOSFET short circuit
4 FLASHES Contactor fault or motor open circuit
6 FLASHES Accelerator wire off fault
7 FLASHES Too low or too high battery voltage or BDI cutout operating
8 FLASHES Over temperature or timed cutback
10 FLASHES Power-up Autozero function has not yet been completed

SEVCON - motor controller
POWERPAK error codes

Green LED Description
ON No fault
OFF No power-up, internal fault
1 FLASH Personality out of range
2 FLASHES Invalid start procedure - sequence error
3 FLASHES Motor or mosfet short circuit
4 FLASHES Motor open circuit or contactor fault
6 FLASHES Accelerator fault, Speed probe fault
7 FLASHES Battery voltage fault, BDI cutout
8 FLASHES Thermal cutback
9 FLASHES Contactor coil open circuit
12 FLASHES CAN-bus fault

SEVCON - motor controller
SC2000 error codes

Green LED Description
ON No fault
OFF No power-up, internal fault
1 FLASH Personality out of range, CRC fault
2 FLASHES Invalid start procedure - sequence error, steer switch sequence, two directions together
3 FLASHES Mosfet short circuit or bypass contactor welded
4 FLASHES Contactor circuit open or shorted
6 FLASHES Potentiometer fault (accelerator, speed probe, steer pot)
7 FLASHES Battery voltage fault, BDI cutout
8 FLASHES Thermal cutback, heatsink too hot, over 75 deg.C
9 FLASHES Contactor coil short circuit