GE - SCR motor controller
EV-100ZX error codes

LED display Description
-01 No seat / deadman switch input
-02 Forward directional switch is closed on initial power up
-03 Forward directional switch is closed on initial power up
-04 Start switch input low after initial start up
-05 Start switch or brake switch fails to close
-06 Accelerator depressed with no direction selected
-07 Accelerator input voltage too high
-08 Accelerator input voltage too low on power up after initial key switch closure
-09 Both forward and reverse directional switches are closed at the same time
-11 Start switch closed on power up after initial key switch closure
-15 Battery volts too low
-16 Battery volts too high
-17 Invalid card type selection
-21 Accelerator input is less than 0.25 volts
-23 Forward and reverse contactor coil current low
-24 T2 voltage low, less than 12% battery volts
-25 1A contactor does not drop out or drops out slowly
-26 Shorted coil driver for SP or FW contactor
-41 Open thermal protector (TP) or control over temperature
-42 Control motor current sensor input missing - green wire
-43 Control motor current sensor input missing - yellow wire
-44 SCR 1REC did not turn off properly
-45 SCR 1REC did not turn on properly
-46 Look ahead test for T2 volts - greater than 85% of battery volts
-47 SCR 2REC does not turn properly
-48 Look ahead test for T2 volts -Less than 12% of battery volts
-49 SCR 5REC does not turn on properly
-50 Capacitor volts low
-51 Excessive capacitor voltage when motor current is high
-52 Excessive capacitor voltage when motor current is low
-53 SCR 1 REC fails to turn off during plug cycle
-54 Shorted F, R or 1A contactor coil driver
-57 Current sensor input voltage polarity check
-70 Regen current sensor input missing - yellow wire
-71 Regen current sensor input missing - green wire
-72 Regen contactor does not pick up
-73 Regen contactor does not drop out or drops out slowly
-74 Regen contactor picks up too slow
-75 SCR 1REC fails to turn off during Regen
-76 Capacitor overvoltage during Regen
-90 User defined status code, terminal 1 shorted to negative
-91 User defined status code, terminal 3 shorted to negative
-92 User defined status code, terminal 4 shorted to negative
-93 User defined status code, terminal 5 and 6 shorted to negative
-94 User defined status code, terminal 8 and 10 shorted to negative
-95 User defined status code, terminal 11 and 12 shorted to negative
-99 Maintenence Alert Code
-117 Invalid pump card type selection
-123 Defective Pump contactor coil circuit
-124 Pump T2 voltage low - greater than 12% battery volts
-125 Pump 1A contactor does not drop out or drops out slowly
-141 Open pump thermal protector (TP) or pump control over temperature
-142 Control pump motor current sensor input missing - green wire
-143 Control pump motor current sensor input missing - yellow wire
-144 Pump SCR 1REC did not turn off properly
-145 Pump SCR 1REC did not turn on properly
-146 Look ahead test for pump T2 volts - greater than 85% of battery volts
-147 Pump SCR 2REC does not turn properly
-148 Look ahead test for pump T2 volts -Less than 12% of battery volts
-149 Pump SCR 5REC does not turn on properly
-150 Pump controller capacitor volts low
-151 Excessive pump capacitor voltage when motor current is high
-152 Excessive pump capacitor voltage when motor current is low
-154 Shorted pump 1A contactor coil driver
-157 Pump current sensor input voltage polarity check